CTC 462 LAB 6 (Drainage Areas/Design Frequencies)

 1. Using the Torne Valley plans and the attached USGS topo map (1"=1000"), delineate and determine the drainage area for each cross culvert to be replaced:

Approx. Loc.

Exist. Size/Length

Inv. In

Inv. Out

Comments

Sta 29+00

15" CMP / 30'

300.78

299.55

Abandon in place

Sta 35+00

18" CMP / 35'

308.54

306.66

 

Sta 42+55

18" CMP / 25'

297.36

295.36

 

Sta 46+25

36" CMP / 40'

296.09

295.31

Poor condition

Sta 48+60

15" CMP / 40'

299.37

297.48

To culv @ 46+25

Sta 54+80

18" CMP/ 35'

n.a.

302.66

To culv @ 46+25

Sta 59+45

48" CMP / 40'

307.91

304.91

 

Sta 61+05

48" RCP / 50'

306.88

306.20

 

Sta 77+00

48" CMP / 60'

374.0+/-

372.0+/-

To culv @ Sta 61+05

Sta 92+00

48x48RCB / 60'

450.9

450.4

 

Sta 94+15

36" CMP/ 32'

451.80

450.55

Not structurally sound

Sta 94+15

30" CMP / 32'

452.81

451.25

Not structurally sound

Red indicates stations at which culverts were replaced with new culverts.

2. Using Chapter 8 of the Highway Design Manual, determine the design frequencies to be used for analyzing the proposed cross culverts and the roadside ditches.