CTC 440 - Homework 15 (Hydraulic Radius/Size Pipe)

1.     Determine by hand (using the attached Table) the hydraulic radius of a 24" pipe flowing:

1/4 full
half full
3/4 full
almost completely full (but not under pressure)

 

Check your answers by using “Flowmaster”.  Print out the results.

2.     Given:

·        32l-acre watershed

·        Time of concentration = 40 minutes

·        Single family residential neighborhood near Stewart Airport

·        Round concrete pipe

·        2% pipe slope

Size the pipe for a 25-year storm and check the approximate velocity.  (Note:  Although the drainage area is greater than 200 acres use the rational formula to determine the peak flow).

 

3.      Read the following article:  Lessons From Katrina, Todd Litman (Draft) 2005